config.yml 1.6 KB

1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071727374757677
  1. Inputs:
  2. - SiemensCPU: siemens.snap7_connect
  3. enabled: False
  4. host: "192.168.0.10"
  5. - SiemensServer: siemens.snap7_server
  6. enabled: True
  7. port: 102
  8. - Balluff: balluff.balluff_html
  9. enabled: False
  10. - AllenBradleyCPU: rockwell.allen_bradley_connect
  11. host: "192.168.1.15"
  12. enabled: True
  13. - Replay: replay_influxdb
  14. enabled: False
  15. url: "http://influxdb:8086"
  16. token: "XPBViJ3s4JL9_wPffwd5M2EgXj5hcUgT0n4jNhv7m6-NC-6SSxQ3run4kXtWBvOk-FYr1VG5Tj5WcoHgjge9jw=="
  17. org: "laempe"
  18. bucket: "energy-monitor"
  19. start_time: 03.05.2022 07:00:00
  20. Middlewares:
  21. - PrintStats: debug
  22. enabled: False
  23. - TimeCorrelation: time_correlation
  24. submodules:
  25. - PrintStats: debug
  26. Outputs:
  27. - CSVStorage: csv_file
  28. path: logs
  29. - InfluxDB: influxdb
  30. url: "http://influxdb:8086"
  31. token: "XPBViJ3s4JL9_wPffwd5M2EgXj5hcUgT0n4jNhv7m6-NC-6SSxQ3run4kXtWBvOk-FYr1VG5Tj5WcoHgjge9jw=="
  32. org: "laempe"
  33. bucket: "energy-monitor"
  34. - SqliteDB: sqlite_db
  35. enabled: False
  36. Logging:
  37. version: 1
  38. formatters:
  39. standard:
  40. format: "%(asctime)s [%(levelname)s] \t%(name)s: \t%(message)s"
  41. handlers:
  42. default:
  43. level: INFO
  44. formatter: standard
  45. class: logging.StreamHandler
  46. stream: ext://sys.stderr
  47. loggers:
  48. '':
  49. handlers:
  50. - default
  51. level: DEBUG
  52. propagate: false
  53. inputs.rockwell.allen_bradley_connect:
  54. handlers:
  55. - default
  56. level: WARNING
  57. propagate: false
  58. snap7.server:
  59. handlers:
  60. - default
  61. level: WARNING
  62. propagate: false
  63. __main__:
  64. handlers:
  65. - default
  66. level: DEBUG
  67. propagate: false